SEK-8102 Smart inertia experiment
  • Details


Experiments

1.Measuring the twist constant of instrument

2.Measuring rotational inertia of plastic cylinder, metallic cylinder, globoid and metal bar.

3.Verify the parallel-axis theorem by changing the position of sliding block on the metal bar.


Features

1.The instrument use steel structure, using three feet nut stent to adjust the horizontal height, fixing the spirit level on the stent.

2.standard configuration of different kinds of rigid bodies: cylinder, metal hollow cylinders, globe and metal bar with sliding block

3.Adopt new SCM to control system for the reason of high precision, strong function, stable property and reliable.

4.Millisecond Timer and Counter,(equip with millisecond timer and counter).

    a)Adopt SCM to control circuits, it can measure the period of object rotation and movement.

    b)Automatically save and record multi-group data, and it can calculate the average value precisely.

It can be used as general purpose timer, user can master it by membrane switch on the panel and preset by nixie tube to manage the data.


Specifications

Millisecond timing counter

Timing function: five LED digital display, timing at 999.99ms

Counting function:0-30 setting randomly

Experimental sample

Plastic cylinder (2), metal cylinder, nylon ball and metal bar

Relative error: ≤5%


Experiments and Data

1. Measuring the torsion constant of torsional pendulum “K”

2. Measuring the rotational inertia of plastic cylinder, metal cylinder, nylon ball and metal bar

微信图片_20200416154440.png

微信图片_20200416154716.png

3. change the position of sliding block on the metal bar to verify parallel-axis theorem of rotational inertia

I0 = 0.179 x 10-4 kg•m2, IMeas.= 0.232 x 10-4 kg•m2, ITheo.=0.3719 x 10-4 kg•m2